Connection cables#
The FlexiBowl® connection cables can be purchased separately as an option, in lengths of 3, 5 or 10 meters. This page summarizes the cables available in the catalog, their prerequisites and their pinouts.
Note
The cables for the Bulk Feeders (Modbus RTU cable and controller Input cable) are described on the Bulk Feeder Accessories and Options page.
Warning
Connect and disconnect the cables only when the device is switched off and disconnected from the power supply.
Summary#
Cable |
Prerequisites |
Compatible sizes |
Lengths |
|---|---|---|---|
Digital I/O option (purchased separately) |
All sizes |
· 3 · 5 · 10 m |
|
FlexiBowl® with external rack |
FlexiBowl® 200 · 350 |
· 3 m included in the supply; · 5 · 10 m |
|
None |
All sizes |
· 3 · 5 · 10 m |
|
None |
All sizes |
· 3 · 5 · 10 m |
Catalog items#
Cable |
3 m |
5 m |
10 m |
|---|---|---|---|
I/O option |
FlexiBowl cable for I/O option, 3m |
FlexiBowl cable for I/O option, 5m |
FlexiBowl cable for I/O option, 10m |
Remote cabinet (rack) |
Cable for remote electronic cabinet, 3m |
Cable for remote electronic cabinet, 5m |
Cable for remote electronic cabinet, 10m |
Power supply |
FlexiBowl Power Supply Cable, 3m |
FlexiBowl Power Supply Cable, 5m |
FlexiBowl Power Supply Cable, 10m |
Ethernet |
Ethernet Cable 3m |
Ethernet Cable 5m |
Ethernet Cable 10m |
I/O option cable#
Description. Cable for connecting the signals of the Digital I/O option, which allows the FlexiBowl® to be controlled from a PLC via digital inputs and outputs, without Ethernet communication. Signals and command coding: Digital I/O.
Prerequisites |
Digital I/O option, purchased separately and not included in the standard configuration. |
||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FlexiBowl® side connector |
19-pin I/O connector I/O connector pinout (19 pin)
|
||||||||||||||||||||||||||||||||||||||||||||||||
Available lengths |
· 3 m · 5 m · 10 m |
Cable for remote electronic cabinet (rack)#
Description. Connection cables between the external rack and the FlexiBowl®. The rack communicates with the machine through 4 dedicated cables, each to be connected exclusively to the port with the matching label. Connection procedure: Connection between Rack and FlexiBowl®.
Prerequisites |
FlexiBowl® with external rack (no option to purchase). |
|---|---|
Compatible sizes |
· FlexiBowl® 200 · FlexiBowl® 350 |
Available lengths |
· 3 m (included in the supply) · 5 m · 10 m |
Attention
Connect each cable to the port with the matching label (e.g. MOTOR ↔ MOTOR, C-A SIGNAL ↔ C-A SIGNAL). A crossed connection can damage the system.
Cable |
Connector |
Function |
||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C-ETH FB |
M12 D-code C-ETH FB pinout (M12 D-code)
|
Ethernet connection between rack and FlexiBowl® |
||||||||||||||||||||||||||
MOTOR |
9-pin MOTOR pinout (9 pin)
|
Motor power supply and STO signals |
||||||||||||||||||||||||||
C-A SIGNAL |
12-pin C-A SIGNAL pinout (12 pin)
|
Analog signals |
||||||||||||||||||||||||||
C-B SIGNAL |
19-pin C-B SIGNAL pinout (19 pin)
|
Digital signals, including status LED activations |
Power supply cable#
Description. Mains power cable, to be connected to the POWER SUPPLY connector of the standard electrical panel (FlexiBowl® 500 – 1200) or of the rack (FlexiBowl® 200 / 350). Connection procedure: FlexiBowl® 500 – 1200 — Standard Electrical Panel · FlexiBowl® 200 / 350 — External Rack.
Prerequisites |
None. Device switched off, earth connection mandatory. The connector houses 2 protection fuses. |
|---|---|
Compatible sizes |
All FlexiBowl® sizes |
Permitted voltage |
120–230 Vac, 50/60 Hz (Electrical Technical Data) |
Available lengths |
· 3 m · 5 m · 10 m |
Label (FlexiBowl® side) |
Type |
Color |
|---|---|---|
L1 |
Phase |
Brown |
N1 |
Neutral |
Blue |
PE1 |
Earth |
Yellow/Green |
Attention
Connect the power supply last, with the FlexiBowl® switched off. The earth connection is mandatory and must be verified before every power-up.
Ethernet cable#
Description. Cable for the Ethernet connection of the FlexiBowl® to the system (C-ETH connector of the standard panel or C-ETH IN of the rack). It enables communication with the FlexiBowl®, which can also be accessed via a web browser.
Prerequisites |
None. With the FlexiBowl® powered, the Ethernet connection is mandatory: if it is absent, the machine enters the ERROR state (red Ready/Fault LED). |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Compatible sizes |
All FlexiBowl® sizes |
|||||||||||||||||||||||||
Connectors |
FlexiBowl® side: M12 D-code M12 D-Code and RJ45 pinout
RJ45 pins 4, 5, 7 and 8 are not assigned. |
|||||||||||||||||||||||||
Available lengths |
· 3 m · 5 m · 10 m |