Electrical Technical Data#
The nominal electrical parameters applicable to all variants of the FlexiBowl® FB 3.0 family are given below.
Power Supply Data#
General Parameters#
Nominal voltage: 230 / 120 Vac
Nominal frequency: 50 Hz / 60 Hz
Nominal Absorbed Current#
The absorbed current varies depending on the installed model. The value is useful for sizing the upstream protection and the power supply cables.
Device |
Nominal current |
|---|---|
FlexiBowl® 200 |
0.48 A |
FlexiBowl® 350 |
0.56 A |
FlexiBowl® 500 |
1.12 A |
FlexiBowl® 650 |
1.12 A |
FlexiBowl® 800 |
1.83 A |
FlexiBowl® 1200 |
3.23 A |
Installed Nominal Power#
The nominal power varies depending on the installed model and is the reference value for sizing the power supply or the electrical cabinet.
Device |
Nominal power |
|---|---|
FlexiBowl® 200 |
345 W |
FlexiBowl® 350 |
345 W |
FlexiBowl® 500 |
460 W |
FlexiBowl® 650 |
460 W |
FlexiBowl® 800 |
575 W |
FlexiBowl® 1200 |
920 W |
Electrical Protections#
Fuses (internal)#
The power connector is equipped with a holder for 2 fast-acting fuses, which protect the device against possible electrical faults. The nominal values per model are as follows:
Device |
Fuse |
|---|---|
FlexiBowl® 200 |
3 A |
FlexiBowl® 350 |
3 A |
FlexiBowl® 500 |
3 A |
FlexiBowl® 650 |
3 A |
FlexiBowl® 800 |
4 A |
FlexiBowl® 1200 |
5 A |
Residual-Current Circuit Breaker (upstream)#
Each FlexiBowl® model requires an upstream residual-current circuit breaker with type D tripping curve, sized per model as indicated in the table. This protection is the responsibility of the integrator/customer’s installation and is separate from the internal fuses described above.
Device |
Residual-current circuit breaker |
|---|---|
FlexiBowl® 200 |
2.00 A |
FlexiBowl® 350 |
2.00 A |
FlexiBowl® 500 |
4.00 A |
FlexiBowl® 650 |
4.00 A |
FlexiBowl® 800 |
4.00 A |
FlexiBowl® 1200 |
6.00 A |
Electrical Protection Class#
Protection class: Class I
Protection is achieved through basic insulation and the connection of all metal exposed parts to the protective conductor (PE – system ground). Since this is Class I protection (and not double insulation), the ground connection is an integral part of the device’s safety system.
Earthing#
The device must be connected to the system ground circuit before any other operation.
Attention
Before switching on the FlexiBowl®, verify that the device is correctly earthed to the general system.
General Notes and Warnings#
Attention
All connection operations must be performed with the device switched off and disconnected from the power supply.
Attention
The ground connection is mandatory and must be verified before every power-up.
Attention
In case of an anomaly indicated by the red LED (Ready/Fault), refer to the model-specific fault table.
Attention
For further technical information or assistance, contact ARS s.r.l. – FlexiBowl® Division.