Electrical Technical Data#

The nominal electrical parameters applicable to all variants of the FlexiBowl® FB 3.0 family are given below.


Power Supply Data#

General Parameters#

  • Nominal voltage: 230 / 120 Vac

  • Nominal frequency: 50 Hz / 60 Hz

Nominal Absorbed Current#

The absorbed current varies depending on the installed model. The value is useful for sizing the upstream protection and the power supply cables.

Device

Nominal current

FlexiBowl® 200

0.48 A

FlexiBowl® 350

0.56 A

FlexiBowl® 500

1.12 A

FlexiBowl® 650

1.12 A

FlexiBowl® 800

1.83 A

FlexiBowl® 1200

3.23 A

Installed Nominal Power#

The nominal power varies depending on the installed model and is the reference value for sizing the power supply or the electrical cabinet.

Device

Nominal power

FlexiBowl® 200

345 W

FlexiBowl® 350

345 W

FlexiBowl® 500

460 W

FlexiBowl® 650

460 W

FlexiBowl® 800

575 W

FlexiBowl® 1200

920 W


Electrical Protections#

Fuses (internal)#

The power connector is equipped with a holder for 2 fast-acting fuses, which protect the device against possible electrical faults. The nominal values per model are as follows:

Device

Fuse

FlexiBowl® 200

3 A

FlexiBowl® 350

3 A

FlexiBowl® 500

3 A

FlexiBowl® 650

3 A

FlexiBowl® 800

4 A

FlexiBowl® 1200

5 A

Residual-Current Circuit Breaker (upstream)#

Each FlexiBowl® model requires an upstream residual-current circuit breaker with type D tripping curve, sized per model as indicated in the table. This protection is the responsibility of the integrator/customer’s installation and is separate from the internal fuses described above.

Device

Residual-current circuit breaker

FlexiBowl® 200

2.00 A

FlexiBowl® 350

2.00 A

FlexiBowl® 500

4.00 A

FlexiBowl® 650

4.00 A

FlexiBowl® 800

4.00 A

FlexiBowl® 1200

6.00 A

Electrical Protection Class#

  • Protection class: Class I

Protection is achieved through basic insulation and the connection of all metal exposed parts to the protective conductor (PE – system ground). Since this is Class I protection (and not double insulation), the ground connection is an integral part of the device’s safety system.

Earthing#

The device must be connected to the system ground circuit before any other operation.

Attention

Before switching on the FlexiBowl®, verify that the device is correctly earthed to the general system.


General Notes and Warnings#

Attention

All connection operations must be performed with the device switched off and disconnected from the power supply.

Attention

The ground connection is mandatory and must be verified before every power-up.

Attention

In case of an anomaly indicated by the red LED (Ready/Fault), refer to the model-specific fault table.

Attention

For further technical information or assistance, contact ARS s.r.l. – FlexiBowl® Division.