Software Comparison#

This page compares the main software differences between FlexiBowl® 2.0 and FlexiBowl® 3.0, with the aim of guiding the user in understanding the new features and operational changes introduced by the new generation.

Important

Before reading the contents of this page, it is good practice to be familiar with the information given on the Software Interface page


1. Available communication protocols#

Protocol

FlexiBowl® 2.0

FlexiBowl® 3.0

TCP/IP – UDP

✓

✓ (TCP Server)

EtherNet/IP

✓

✓

Profinet

✗

✓

Modbus

✗

✓

Digital I/O

✓

✓ (optional)


2. User interface: what it looks like and how to access it#

FlexiBowl® 2.0 — Software Parameters

Desktop interface called FlexiBowl® Parameters, to be installed on the control PC.

Installation and access:

  1. Install the FlexiBowl® Parameters program on the PC (supplied by ARS).

  2. Connect the PC to the FlexiBowl® via an Ethernet cable (direct LAN or via a switch).

  3. Start the program and enter the FlexiBowl® IP address to connect.

From the Main Commands screen, the Move, Shake and Option panels can be accessed via tabs at the top.

FlexiBowl® 3.0 — Web Interface

Fully web-based interface: it requires no installation. A modern browser is all that is needed.

Access:

  1. Connect the PC to the FlexiBowl® via Ethernet.

  2. Open the browser and type the FlexiBowl® IP address in the address bar.

  3. The interface Home page opens.

Interface structure:

The side menu includes pages dedicated to each operating function (Main Command, Jog Motor, Setup, Monitor, etc.), accessible directly from the browser.

Note

If the system in use is FlexiVision One, the configuration is managed from its dedicated interface. It is not necessary to use the FlexiBowl® software interface described in this section.


3. How to change the IP address#

FlexiBowl® 2.0
  1. Use the program supplied on the USB drive.

  2. Connect the FlexiBowl® via Ethernet cable.

  3. Switch on the device.

  4. Start the program.

  5. In the IP Address box, enter the address: 192.168.1.10 (The connected PC must be in the same Class B subnet mask — 255.255.0.0)

  6. Press Ping → “FlexiBowl® found” pop-up.

  7. Press Ok to enable CONNECT and start the connection.

  8. After connecting, the home screen will be displayed.

FlexiBowl® 3.0
  1. Open the browser and access the interface via the current IP.

  2. From the side menu, open the Setup page.

  3. Click Get IP to read the current network parameters.

  4. Enter the new IP address in the dedicated fields and click Set IP.

  5. Click Apply to confirm, then Reboot to make the changes effective.

Note

FlexiBowl® 2.0 — If a previous version of the program is installed, it must be uninstalled first.

Important

FlexiBowl® 3.0 — After the reboot, reconnect to the FlexiBowl® using the new IP address that was set.


4. How to manage movements#

FlexiBowl® 2.0

Movements are configured and tested from Main Commands, with three panels:

  • Move: sets Acceleration, Deceleration, Speed and Angle via slider or numeric field. Test Move executes the movement with the set values.

  • Shake: parameters CCW Angle, CW Angle, Count, Acceleration, Deceleration and Speed. Test Shake executes the shake.

  • Try Commands: combines several commands into a sequence with a configurable loop, selecting from All Commands and adding to Selected Commands.

For production via protocol, ASCII commands (e.g. QX2 for Move, QX6 for Shake) are sent through the configured TCP/UDP channel.

FlexiBowl® 3.0

Movements are organized in sequences (up to 20), configurable from the Main Command page. Each sequence contains up to 10 command slots (Move, Shake, Flip, Blow).

From the Main Command page it is possible to:

  • Select the sequence via Select the sequence.

  • Set all parameters in the numeric fields.

  • Add commands with Command Available + ADD; reorder them with UP/DOWN; remove them with DELETE or empty the list with CLEAR.

  • Test with TEST SEQUENCE or start production with RUN.

The Jog Motor page allows continuous rotation (positive Speed = clockwise, negative = counterclockwise) with integrated Flip and Blow.

For production via protocol: 10[0]% for Sequence 1 via TCP, or ControlWord 10 via EtherNet/IP or Profinet.


5. How to change parameters#

FlexiBowl® 2.0

Operating parameters are modified in two ways:

  • Graphical interface: sliders or numeric fields in the Move and Shake screens of Main Commands.

  • Via protocol (runtime): commands RW (Write) and RL (Read) via TCP/UDP. Values must be multiplied by the machine’s reduction factor (obtained with the command RR114), since the parameters are expressed in internal driver units.

FlexiBowl® 3.0

Parameters are modified in three ways:

  • Web interface: directly in the numeric fields of the Main Command page for each sequence.

  • Via WRITE protocol: ControlWord WRITE block with formula N × 100 + offset_parametro

  • Via READ protocol: ControlWord READ block with formula 10000 + N × 100 + offset_parametro


Practical example: Move + Shake on FlexiBowl® 800#

The scenario is as follows: execute a Move of 360°, then a Shake, then a 200 ms wait.

FlexiBowl® 2.0 — TCP command sequence

Parameters must be scaled using the machine’s reduction factor:

QX7                     → Turn on backlight
RR114                   → Read reduction factor
reduction_factor = RX 1
 
RL1 (50 × reduction_factor), RW11   → Acceleration Move = 50%
RL1 (50 × reduction_factor), RW12   → Deceleration Move = 50%
RL1 (35 × reduction_factor), RW13   → Speed Move = 35%
RL1 (360 × reduction_factor), RW14  → Angle Move = 360°
QX2                     → Execute Move
 
RL1 (50 × reduction_factor), RW15  → Acceleration Shake = 50%
RL1 (50 × reduction_factor), RW16  → Deceleration Shake = 50%
RL1 (50 × reduction_factor), RW110 → Speed Shake = 50%
RL1 (30 × reduction_factor), RW18  → Angle CW Shake = -30°
RL1 (30 × reduction_factor), RW19  → Angle CCW Shake = -45°
RL1 2, RW17                           → Count Shake = 2
QX6                     → Execute Shake

The 200 ms wait is handled by the calling system (robot or PLC).

FlexiBowl® 3.0 — Web interface configuration

From the Main Command page, select SEQUENCE 1 and set:

Parameter

Value

Acceleration Move

50 %

Deceleration Move

50 %

Speed Move

35 %

Angle Move

360°

Acceleration Shake

50 %

Deceleration Shake

50 %

Speed Shake

50 %

Ccw Angle Shake

−45°

Cw Angle Shake

−30°

Count Shake

2

Add to the list: FLB_MOVE → FLB_SHAKE. Check Backlight from the Option page. The 200 ms wait is handled by adding FLB_WAIT to the list or on the calling system side.

To execute the sequence via TCP:

10[0]%    → Execute Sequence 1

The system responds with 10[0] as confirmation.


6. How to read alarms#

FlexiBowl® 2.0

Alarms are consulted from Monitor → Alarm Status of the FlexiBowl® Parameters program. The screen shows the driver states with LED indicators (green = OK, red = error). The Driver Status screen shows all operating variables in real time.

Alarm reset via protocol:

Chr(0)Chr(7)QX12Chr(13)    → Reset alarm and re-enable motor
FlexiBowl® 3.0

Alarms are consulted from the Monitor page (tabs: I/O Status, Driver Status, Alarm Status).

Via protocol, the alarm signal is exposed by In_Error (BOOL) and the active code by ErrorCode (UDINT):

InError%         → InError[1]% if there is an error, InError[0]% if OK
ErrorCode%       → ErrorCode[N]% with the code of the active error

Alarm reset:

  • Via TCP protocol: Reset%

  • Via digital variable: rising edge on the Reset input signal (BOOL)

Warning

Before performing the reset, identify and resolve the cause of the error. The system will not execute new motion commands while an active error is present.

Note

For the complete list of error codes, refer to the Error Codes section


7. Circular Tracking mode#

FlexiBowl® 2.0

The Circular Tracking mode is an option that can be purchased separately and allows the FlexiBowl® to be kept in continuous rotation (jog) by synchronizing the encoder signal with the pick robot.

Required hardware:

  • Connection to the internal encoder via the control panel connector (TTL quadrature signal, 4000 counts/rev on the motor; for FlexiBowl® 500/650/800 with 1:3 reduction → 12000 counts/rev on the disc).

  • Alternatively, external encoder (incremental, TTL RS422, ≥ 12000 ppr) on the shaft integral with the driven pulley.

Main Circular Tracking commands (via TCP/UDP):

Command

Description

JA<valore>

Acceleration/deceleration in rev/s²

JL<valore>

Deceleration (if different from JA, send after JA)

JS<valore>

Rotation speed in rev/s

CC<valore>

Current delivered to the motor

DI1

Clockwise direction

DI-1

Counterclockwise direction

CJ

Start jog (continuous rotation)

SJ

Stop jog (with JL ramp)

IL2 / IH2

Enable / disable Flip

IL3 / IH3

Enable / disable Blow

Recommended parameters:

JA0.2    → acceleration 0.2 rev/s²
JL0.2    → deceleration 0.2 rev/s²
JS0.2    → speed 0.2 rev/s
CC1.3    → motor current
DI1      → clockwise rotation

Flip and Blow must be implemented through a background program with an iterative loop that toggles the valve state.

FlexiBowl® 3.0

Jog mode is natively integrated in the Jog Motor page — without additional hardware options.

Jog movement parameters:

Parameter

Unit

Description

Acceleration

%

Acceleration ramp at start

Deceleration

%

Deceleration ramp at stop

Speed

%

Speed — positive = clockwise; negative = counterclockwise

Accessory functions during Jog:

  • Flip Enable: automatic cyclic flip with Flip Duration, Flip Pression, Flip Pause.

  • Blow Enable: automatic cyclic blow with Blow Duration, Blow Pression, Blow Pause, Blow Type (BLOWc, BLOWe, BLOWc+BLOWe).

  • Backlight 1 / 2: backlight toggle, independent of the jog state.

Start and stop:

  • START JOG: starts continuous rotation.

  • STOP JOG: stops with a deceleration ramp.

Control via protocol:

40[0]%    → Start Jog Seq (via TCP)
41[0]%    → Stop Jog Seq (via TCP)

Important

Before starting the jog, verify that the motor is enabled (ENABLE MOTOR active) and that the system state is READY.

Important

With Circular Tracking (FlexiBowl® 2.0), motion control is possible only via Ethernet protocol (TCP/UDP). The Digital I/O protocol is not supported.