Electrical Comparison#

This page compares the main electrical differences between FlexiBowl® 2.0 and FlexiBowl® 3.0, in terms of power supply, connectivity and safety.

Important

Before reading the contents of this page, it is good practice to be familiar with the information given on the Electrical and Pneumatic Specifications page


1. Power supply#

FlexiBowl® 2.0

FlexiBowl® 3.0

AC power supply

110-220 Vac ±5%

110-230 Vac ±5%

Frequency

50/60 Hz

50/60 Hz

Nominal power

150 W

345-920 W (depending on FlexiBowl® size)

DC power supply

Generated internally

Generated internally

Note

FlexiBowl® 3.0 draws a higher nominal power than the previous generation, because the drive electronics are integrated directly into the unit.


2. Ethernet connectivity#

FlexiBowl® 2.0

Standard RJ45 connector.

FlexiBowl® 3.0

M12 D-code connector.


3. Safety#

FlexiBowl® 2.0

To stop the unit safely, the 230 Vac power supply must be completely disconnected.

FlexiBowl® 3.0
../../_images/connettore_STO.png

Integrated Safe Torque Off (STO) function, which allows safe stopping without having to disconnect the power supply.

Note

For details on the STO channels and their wiring, refer to the Electrical Interface page.


4. Summary#

FlexiBowl® 3.0 draws more power than the previous generation because of the integrated drive electronics, but it introduces a more robust Ethernet connector (M12 D-code) and an integrated STO safety function, which removes the need to disconnect the power supply to stop the unit safely.