Replacing the Surface or the Rigid Disc#
Changing the surface or the rigid disc is required when there is a production changeover or when the previous surface or rigid disc is damaged. In any case, it is recommended to change the surface or rigid disc:
Every 3 months when used with particularly sharp components;
Annually in all other cases.
Warning
Make sure the FlexiBowl® is switched off and stationary before proceeding with the replacement of the surface or the disc.
Warning
Some parts involved in the maintenance process described here may have reached high temperatures during operation; make sure to leave the FlexiBowl® switched off long enough for all its parts to be handled safely.
Surfaces (FlexiBowl® 500-650-800-1200)#
What is needed?#
Item/equipment |
Quantity |
|---|---|
H5 hex key |
1 |
Replacement surface |
1 |
Procedure#
Step |
Operation |
|---|---|
1 |
Lift/remove deflectors/brushes (if present) |
2 |
Loosen the fixing screws of the central cap |
3 |
Rotate and remove the central cap |
4 |
Remove the surface and position the new one |
5 |
Refit the central cap and tighten the screws |
Rigid discs#
FlexiBowl® 350-500E#
What is needed?#
Item/equipment |
Quantity |
|---|---|
H5 hex key |
1 |
Replacement rigid disc |
1 |
Procedure#
Step |
Operation |
|---|---|
1 |
Remove the deflectors and the flip barrier assembly |
2 |
Loosen the fixing screws of the central cap |
3 |
Rotate and remove the central cap |
4 |
Remove the disc and position the new one |
5 |
Refit the central cap and tighten the screws |
FlexiBowl®200#
What is needed?#
Item/equipment |
Quantity |
|---|---|
H3 hex key |
1 |
Replacement rigid disc |
1 |
Procedure#
Step |
Operation |
|---|---|
1 |
Remove the central cap |
2 |
Replace the disc |
3 |
Refit the central cap |