Mechanical Interface#

Important

For installation, an area suitable for the dimensions of the machine and of the lifting equipment used must be prepared, paying attention to any obstacles (other machines, walls or the like) along the path that the handling equipment must follow.

Note

The centering pins are optional and not included with the FlexiBowl®.

FlexiBowl® 200#

../../_images/AS000001_Interfaccia.PNG

FlexiBowl® 350#

../../_images/AS000010_Interfaccia.PNG

FlexiBowl® 500/500E#

../../_images/AS000004_interfaccia.PNG

FlexiBowl® 650#

../../_images/AS000008_Interfaccia.PNG

FlexiBowl® 800#

../../_images/AS000006_Interfaccia.PNG

FlexiBowl® 1200#

../../_images/AS000012_Interfaccia.PNG

Emptying interface#

The drilling interfaces and the positions and widths of the exit door for the various FlexiBowl® sizes follow

FlexiBowl® 500#

../../_images/AS000004_interfaccia1.PNG

FlexiBowl® 650#

../../_images/AS000008_Interfaccia1.PNG

FlexiBowl® 800#

../../_images/AS000006_interfaccia1.PNG

FlexiBowl® 1200#

../../_images/AS000012_Interfaccia1.PNG

Rack box (for FlexiBowl® 200 and 350)#

The controller is built in a standard 19″ 3U rack enclosure and is designed for installation in compatible rack cabinets.

A minimum space of 3 rack units (3U) must be reserved for installation. The dimensions and position of the fixing points are shown in the dimensional drawing.

../../_images/rackfix.PNG

Installing the FlexiBowl®#

Step

Operation

1

Place the FlexiBowl® on a stable surface. Pay attention to transport and lifting.

2

Remove the handles and properly fix the FlexiBowl® to the support. The quantity and type of screws required are given in the dedicated section.

3

Remove the eyebolts:

  • FlexiBowl® 500-650-800:

    1. Lock the rotating support of the eyebolts with an M5x12 screw.

    2. Remove the eyebolt.

    3. Cover the M8 hole of the eyebolt with the appropriate plug.

    ../../_images/golf650.PNG
  • FlexiBowl® 1200:

    1. Remove the eyebolt.

    2. Cover the M12 hole of the eyebolt with the appropriate plug.

4

Mount the surface or rigid disc.

5

Proceed with the necessary connections.

Important

Leave about 100 mm of space for the FlexiBowl® power connectors.

Characteristics of the support surface#

Important

Make sure that the machine support surface is flat and horizontal, and suitable to bear its weight.

It is strongly discouraged to mount the FlexiBowl® on an overhanging portion of the machine table. Where this is unavoidable, make sure to stiffen the support surface sufficiently.

../../_images/FB650-nosbalzo.PNG

To guarantee correct operation of the FlexiBowl®, the support surface must have flatness errors of no more than 1 mm, be assembled horizontally and be massive enough not to be affected by the vibrations due to the normal operation of the FlexiBowl®, the robot and any other moving parts present in the layout. Indications on the minimum dimensions and weight required for mounting the FlexiBowl® are given in the table below; from these data, taking into account the material used for the plate, the minimum required thickness can be derived.

../../_images/pianali.PNG

Model

Plate dimensions AxA [mm]

Weight M [kg]

FlexiBowl® 200

≥ 276x276

≥ 2

FlexiBowl® 350

≥ 442x442

≥ 6

FlexiBowl® 500

≥ 770x770

≥ 16

FlexiBowl® 650

≥ 945x945

≥ 48

FlexiBowl® 800

≥ 1120x1120

≥ 68

FlexiBowl® 1200

≥ 1594x1594

≥ 137

Installing the rack box (for FlexiBowl® 200 and 350)#

To prevent the rack from overheating, it is important to leave clearance zones around it:

../../_images/rackclear.PNG

Dimension

Value

Side distance A

10mm

Top distance B

50mm

Front distance C

100mm

Note

The external rack for FlexiBowl® 200 and 350 is of the standard 3U type.

Note

Two racks can be installed one above the other provided that one of the following conditions is met:

  1. the distance between the two is not less than 100 mm;

  2. a physical barrier made of sheet metal or insulating, self-extinguishing plastic material is installed; in this case the distance between the lower rack and the wall can be reduced to 50 mm; to facilitate the extraction of hot air, the use of a barrier inclined towards the rear side of the rack can be considered.

Tip

It is useful to provide a ventilation system above the rack that forces the extraction of the hot air coming out of the upper surface, especially when several are mounted stacked vertically.