Digital I/O#

Communication with digital I/O is a purchasable option and is not part of the standard FlexiBowl®. The input connector of the new generation of FlexiBowl® supports digital and analog signals for direct integration with a PLC without the need for Ethernet communication.

Inputs available on the main connector#

Type

Signal

Electrical type

Active level

Description

Standard

Bit 1

Digital

0–24Vdc, Active High

Command coding bit (see coding table)

Standard

Bit 2

Digital

0–24Vdc, Active High

Command coding bit

Standard

Bit 3

Digital

0–24Vdc, Active High

Command coding bit

Standard

Bit 4

Digital

0–24Vdc, Active High

Command coding bit

Standard

Bit 5

Digital

0–24Vdc, Active High

Command coding bit

Standard

Latch

Digital

0–24Vdc, Active High

Command execution (rising edge)

Standard

Empty Sensor

Digital

0–24Vdc, Active High

FlexiBowl® empty detection sensor

Standard

Zeroing

Digital

0–24Vdc, Active High

Provision for multi-sector disc fixing sensor

Option

Flip proportional valve feedback

Analog

0–10Vdc

Flip proportional valve feedback signal

Option

Blow proportional valve feedback

Analog

0–10Vdc

Blow proportional valve feedback signal

Option

Strobe Backlight + / −

—

—

External backlight strobe command (diode and fuse protection required)

Option

Strobe Backlight 2+ / 2−

—

—

Secondary external backlight strobe command

STO connector (Safe Torque Off)#

The STO connector is dedicated to the safety function for stopping the motor:

Pin

Signal

Description

1

STO1+

Safe Torque Off 1

2

STO1-

STO1 return

3

STO2+

Safe Torque Off 2

4

STO2-

STO2 return

5

24V

Power supply

6

0V

Ground

Command coding via digital bits (Bit 1–5)#

The 5 digital input bits form a 5-digit binary word that identifies the command to be executed. The command is acquired on the rising edge of the Latch signal.

Binary code (Bit5–Bit1)

Command

00000

Alarm reset

00001

Exe Seq 1

00010

Exe Seq 2

00011

Exe Seq 3

00100

Exe Seq 4

00101

Exe Seq 5

00110

Exe Seq 6

00111

Exe Seq 7

01000

Exe Seq 8

01001

Exe Seq 9

01010

Exe Seq 10

01011

Exe Seq 11

01100

Exe Seq 12

01101

Exe Seq 13

01110

Exe Seq 14

01111

Exe Seq 15

10000

Exe Seq 16

10001

Exe Seq 17

10010

Exe Seq 18

10011

Exe Seq 19

10100

Exe Seq 20

10101

Hopper Activation 1

10110

Hopper Activation 2

10111

Hopper Activation 3

11000

Hopper Activation 4

11001–11111

Spare

Tip

Example: to execute Sequence 5, set Bit1=1, Bit2=0, Bit3=1, Bit4=0, Bit5=0 (binary code 00101) and then send a rising edge on Latch.